Ⅰ. Technical ParametersParameterSpecificationConductor Size2.5mm² (AWG 14 equivalent)StructureSingle-core, 99.97% oxygen-free copperInsulationCross-linked polyethylene (XLPE)SheathUV-resistant, flame-retardant TPEVoltage Rating1000V DC / 600V ACTemperature Range-40°C to +90°CCurrent Capacity32A...

introduction

Ⅰ. Technical Parameters

ParameterSpecification
Conductor Size2.5mm² (AWG 14 equivalent)
StructureSingle-core, 99.97% oxygen-free copper
InsulationCross-linked polyethylene (XLPE)
SheathUV-resistant, flame-retardant TPE
Voltage Rating1000V DC / 600V AC
Temperature Range-40°C to +90°C
Current Capacity32A (continuous @ 90°C ambient)
Bend Radius≥4x cable diameter
CertificationsIEC 62930, TÜV EN 50618, UL 4703
Weight~0.18kg/m

Ⅱ. Key Features

1. Compact Design for Flexibility

  • Ideal for tight spaces in rooftop installations

  • 33% smaller cross-section than 4mm² cables

2. High Conductivity

  • Low DC resistance (≤7.41Ω/km) minimizes power loss

  • Complies with IEC 60228 Class 2 for stranded conductors

3. Weather Resistance

  • UV exposure resistance: ≤5% tensile strength loss after 3000 hours

  • Hydrolysis resistance: Passes 1000-hour water immersion test

4. Safety Compliant

  • Flame retardancy: IEC 60332-1-2 (vertical flame test)

  • Halogen-free and low-smoke emission design

Ⅲ. Application Scenarios

ScenarioUse Case
Residential RooftopPanel-to-inverter connections
Small Commercial5-20kW solar systems
Portable Solar KitsRecreational vehicles, off-grid cabins
Solar LightingStreetlights, garden lighting systems

Ⅳ. Installation Guidelines

  1. Voltage Drop Calculation
    • Max recommended run length: 25m for 5kW systems

    • Use 4mm² cable for distances >25m

  2. Termination
    • Compatible with MC4 connectors and ring terminals

    • Crimping tool calibration required for optimal connection

  3. Environmental Considerations
    • Avoid direct contact with sharp edges

    • Use conduit in areas prone to physical damage

Ⅴ. Performance Comparison

Cable SizeResistance (Ω/km)Current Capacity (A)Max System Power (kW)
1.5mm²12.10253.5
2.5mm²7.41325.0
4mm²4.61417.5

Ⅵ. Packaging & Availability

  • Standard Lengths: 100m, 500m, 1000m reels

  • Color Options: Black (negative) / Red (positive)

  • Customization: Available for branded labeling and custom spool sizes


 


inquiry